Product Details | POWER TRANSFORMER

5950-01-063-8558 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 243179P1, 5950-01-063-8558, 01-063-8558, 5950010638558, 010638558

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 13 AUG 1978 01-063-8558

Cross Reference | NSN 5950-01-063-8558

Part Number Cage Code Manufacturer
243179P1 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-063-8558

Technical Data | NSN 5950-01-063-8558

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 14 TURRET AND 12 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION TAP W/O CENTER TAP SINGLE COMPONENT 2ND PRIMARY MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 98.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY 5.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 108.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 7.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 50.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 4.1 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 3 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.960 INCHES NOMINAL
BODY HEIGHT 2.920 INCHES NOMINAL
BODY WIDTH 2.400 INCHES MINIMUM AND 2.440 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES 5TH SECONDARY TAPPED 120V 10MA,6TH SECONDARY TAPPED 250V 25MA
III MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 2.000 POUNDS
MANUFACTURERS CODE 94117

Restrictions/Controls & Freight Information | NSN 5950-01-063-8558

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable