NSN 5950-01-025-1649 PEI2072, 102277, 18273
Product Details | POWER TRANSFORMER
5950-01-025-1649 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: PEI2072, 102277, 18273, 5950-01-025-1649, 01-025-1649, 5950010251649, 010251649
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 27 JUL 1976 | 01-025-1649 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-01-025-1649
Part Number | Request Date | QTY | Origin |
---|---|---|---|
102277 | 2021-04-96 | 1 | ID |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-025-1649
Technical Data | NSN 5950-01-025-1649
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 16 TURRET |
(NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 15.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 14.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 15.80 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 57.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | SLOT 1ST GROUP SLOT 2ND GROUP THREADED HOLE 3RD GROUP |
MOUNTING FACILITY QUANTITY | 2 1ST GROUP 2 2ND GROUP 4 3RD GROUP |
MOUNTING SLOT WIDTH | 0.218 INCHES NOMINAL 1ST GROUP 0.125 INCHES NOMINAL 2ND GROUP |
THREAD SERIES DESIGNATOR | UNF 3RD GROUP |
NOMINAL THREAD SIZE | 0.190 INCHES 3RD GROUP |
(NON-CORE DATA) THREAD CLASS | 2B 3RD GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND 3RD GROUP |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.250 INCHES NOMINAL 1ST MOUNTING FACILITY 1ST CENTER GROUP 3.075 INCHES NOMINAL 1ST MOUNTING FACILITY 2ND CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.400 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.780 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 5.590 INCHES NOMINAL |
BODY HEIGHT | 4.340 INCHES NOMINAL |
BODY WIDTH | 3.720 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | SIX SECONDARIES |
Restrictions/Controls & Freight Information | NSN 5950-01-025-1649
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-025-1649
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |