NSN 5950-01-009-2028 872539, 9845571, 984557-1
Product Details | POWER TRANSFORMER
5950-01-009-2028 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 872539, 9845571, 984557-1, 5950-01-009-2028, 01-009-2028, 5950010092028, 010092028
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 SEP 1975 | 01-009-2028 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-009-2028
Technical Data | NSN 5950-01-009-2028
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 40 SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 1.180 INCHES MAXIMUM |
BODY HEIGHT | 1.250 INCHES MAXIMUM |
BODY WIDTH | 1.000 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
Restrictions/Controls & Freight Information | NSN 5950-01-009-2028
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-009-2028
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |