NSN 5950-00-994-9209 1196, 7143100, 7143-100
Product Details | POWER TRANSFORMER
5950-00-994-9209 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 1196, 7143100, 7143-100, 5950-00-994-9209, 00-994-9209, 5950009949209, 009949209
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 04 APR 1967 | 00-994-9209 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-00-994-9209
Part Number | Request Date | QTY | Origin |
---|---|---|---|
1196 | 2015-01-09 | 1 | US |
1196 | 2010-08-238 | 1 | US |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-994-9209
Technical Data | NSN 5950-00-994-9209
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG |
(NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP SINGLE COMPONENT 2ND SECONDARY CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 295.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 29.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE AND THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 1ST GROUP 4 2ND GROUP |
THREAD SERIES DESIGNATOR | UNF ALL GROUPINGS |
NOMINAL THREAD SIZE | 0.190 INCHES ALL GROUPINGS |
THREAD QUANTITY PER INCH | 32 ALL GROUPINGS |
(NON-CORE DATA) THREAD CLASS | 2B 1ST GROUP 2A 2ND GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND ALL GROUPINGS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 3.812 INCHES MINIMUM AND 3.938 INCHES MAXIMUM |
BODY HEIGHT | 4.125 INCHES MINIMUM AND 4.312 INCHES MAXIMUM |
BODY WIDTH | 3.188 INCHES MINIMUM AND 3.375 INCHES MAXIMUM |
OVERALL HEIGHT | 4.609 INCHES MINIMUM AND 4.828 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
III MAXIMUM OPERATING TEMP | 80.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5950-00-994-9209
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |