Product Details | POWER TRANSFORMER

5950-00-993-6896 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 5848, 7759989P001, 7759989P1, 9T35Y1841, 5950-00-993-6896, 00-993-6896, 5950009936896, 009936896

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 28 MAR 1967 00-993-6896

Demand History | NSN 5950-00-993-6896

Part Number Request Date QTY Origin
5848 2015-08-224 2

Cross Reference | NSN 5950-00-993-6896

Part Number Cage Code Manufacturer
5848 13483 PRECISION ELECTRONICS, INC.
7759989P001 03538 LOCKHEED MARTIN CORPORATION DIV MST
7759989P1 03538 LOCKHEED MARTIN CORPORATION DIV MST
9T35Y1841 03512 GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-993-6896

Technical Data | NSN 5950-00-993-6896

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 10 SOLDER STUD
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 9.60 AC VOLTS NOMINAL AND 115.20 AC VOLTS NOMINAL AND 117.60 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 122.40 AC VOLTS NOMINAL AND 124.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 2.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING 4.0 WATTS SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 54.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 1.938 INCHES MAXIMUM
BODY HEIGHT 2.750 INCHES MAXIMUM
BODY WIDTH 1.812 INCHES MAXIMUM
OVERALL HEIGHT 3.150 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
NONDEFINITIVE SPEC/STD DATA TF4RX01EA TYPE
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 3.500 POUNDS
MANUFACTURERS CODE 03538
DESIGN CONTROL REFERENCE 7759989P1

Restrictions/Controls & Freight Information | NSN 5950-00-993-6896

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code HH Navy ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-993-6896

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each