Product Details | RADIO FREQUENCY TRANSFORMER

5950-00-989-2608 An item having either a single tapped winding (autotransformer type), or two or more windings designed to furnish inductive reactance and/or transfer electrical energy in circuits by means of a magnetic field. It is so designed that its entire intended range of operations is above 20 Kilohertz (Kilocycles). The minimum value may extend into the audio frequency range (below 20 Kilohertz). It may include integral capacitors, coils, resistors, and adjustable tuning cores. For items having only two active terminals see COIL, RADIO FREQUENCY. Includes types having windings which may be moved with respect to each other. Excludes TRANSFORMER, DISCRIMINATOR.

Part Alternates: 85257071, 8525707-1, 5950-00-989-2608, 00-989-2608, 5950009892608, 009892608

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-989-2608

Cross Reference | NSN 5950-00-989-2608

Part Number Cage Code Manufacturer
8525707-1 02734 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
8525707-1 49671 LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-989-2608

Technical Data | NSN 5950-00-989-2608

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 PIN
FREQUENCY RATING 30.0 KILOHERTZ MINIMUM AND 500.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 1.000 INCHES MAXIMUM
BODY HEIGHT 0.750 INCHES MAXIMUM
BODY WIDTH 0.880 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER FUNCTION INTERSTAGE
MANUFACTURERS CODE 02734
DESIGN CONTROL REFERENCE 8525707-1

Restrictions/Controls & Freight Information | NSN 5950-00-989-2608

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-989-2608

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each