NSN 5950-00-979-8808 9500451400, 950-0451-400, 9992897
Product Details | POWER TRANSFORMER
5950-00-979-8808 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 9500451400, 950-0451-400, 9992897, 5950-00-979-8808, 00-979-8808, 5950009798808, 009798808
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1962 | 00-979-8808 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-979-8808
Technical Data | NSN 5950-00-979-8808
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 15 SOLDER STUD |
(NON-CORE DATA) WINDING TAP LOCATION | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT ALL SECONDARY |
WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL AND 110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 6.40 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 12.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2A SINGLE GROUP |
(NON-CORE DATA) THREAD LENGTH | 0.500 INCHES NOMINAL SINGLE GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 4.281 INCHES MINIMUM AND 4.312 INCHES MAXIMUM |
BODY WIDTH | 3.657 INCHES MINIMUM AND 3.688 INCHES MAXIMUM |
OVERALL HEIGHT | 6.291 INCHES MINIMUM AND 6.322 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
Restrictions/Controls & Freight Information | NSN 5950-00-979-8808
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |