Product Details | POWER TRANSFORMER

5950-00-978-9278 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 27V13, 5950-00-978-9278, 00-978-9278, 5950009789278, 009789278

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-978-9278

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-978-9278

Technical Data | NSN 5950-00-978-9278

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 7 SOLDER STUD
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 80.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 900.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 380.0 HERTZ MINIMUM AND 1.6 KILOHERTZ MAXIMUM SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.313 INCHES NOMINAL
BODY HEIGHT 3.125 INCHES NOMINAL
BODY WIDTH 2.063 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 85.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 2.000 POUNDS

Restrictions/Controls & Freight Information | NSN 5950-00-978-9278

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information