Product Details | PULSE TRANSFORMER

5950-00-964-1326 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.

Part Alternates: G2706, 5950-00-964-1326, 00-964-1326, 5950009641326, 009641326

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-964-1326

Cross Reference | NSN 5950-00-964-1326

Part Number Cage Code Manufacturer
G2706 72928 GULTON INDUSTRIES INC GUDEMAN DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-964-1326

Technical Data | NSN 5950-00-964-1326

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 WIRE LEAD
DC RESISTANCE RATING IN OHMS 43.000 SINGLE COMPONENT 1ST SECONDARY 47.000 SINGLE COMPONENT 2ND SECONDARY 38.000 SINGLE COMPONENT SINGLE PRIMARY
PRIMARY TO SECONDARY TURN RATIO 1 TO 1 TO 1 SINGLE COMPONENT
(NON-CORE DATA) PULSE DURATION IN MICROSECONDS 13.000 SINGLE COMPONENT
(NON-CORE DATA) PULSE RISE TIME IN MICROSECONDS 0.150 SINGLE COMPONENT
PULSE REPETITION RATE 1.0 KILOHERTZ SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.562 INCHES NOMINAL
BODY HEIGHT 0.465 INCHES NOMINAL
BODY WIDTH 0.562 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-964-1326

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable