NSN 5950-00-899-9326 Y60212, Y6021-2, 3627585
Product Details | AUDIO FREQUENCY TRANSFORMER
5950-00-899-9326 A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.
Part Alternates: Y60212, Y6021-2, 3627585, 362-7585, 5950-00-899-9326, 00-899-9326, 5950008999326, 008999326
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 10 FEB 1967 | 00-899-9326 | 00780 ( TRANSFORMER, AUDIO FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-899-9326
Related Products | NSN 5950-00-899-9326
Technical Data | NSN 5950-00-899-9326
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
WINDING OPERATING CURRENT | 20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
IMPEDANCE RATING IN OHMS | 20.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
(NON-CORE DATA) FREQUENCY RESPONSE TOLERANCE IN DECIBELS | -1.0 TO 1.0 SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
MOUNTING METHOD | TERMINAL SINGLE GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 1.125 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 1.125 INCHES NOMINAL |
BODY HEIGHT | 0.825 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
III TRANSFORMER FUNCTION | LINE |
(NON-CORE DATA) DUMMY TERMINAL QUANTITY | 1 |
Restrictions/Controls & Freight Information | NSN 5950-00-899-9326
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-899-9326
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | A | Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |