Product Details | POWER TRANSFORMER

5950-00-899-9197 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: BC4009, C5073, SA8999197, SA8999-197, TM341, TM-341, 100867, 4009, 50758, 5950-00-899-9197, 00-899-9197, 5950008999197, 008999197

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-899-9197

Demand History | NSN 5950-00-899-9197

Part Number Request Date QTY Origin
100867 2020-07-212 30 DIBBS
4009 2020-07-212 30 DIBBS
50758 2020-07-212 30 DIBBS
C5073 2020-07-212 30 DIBBS
SA8999-197 2020-07-212 30 DIBBS
5950-00-899-9197 2017-03-89 109 DIBBS
5950-00-899-9197 2014-03-72 76 DIBBS
5950-00-899-9197 2013-05-139 45 DIBBS
5950-00-899-9197 2013-04-107 10 DIBBS
5950-00-899-9197 2013-04-92 10 DIBBS
5950-00-899-9197 2012-08-235 29 DIBBS
100867 2011-05-124 1 US
5950-00-899-9197 2009-11-314 18 DIBBS
5950-00-899-9197 2009-07-208 62 DIBBS
5950-00-899-9197 2008-12-350 3 DIBBS
5950-00-899-9197 2008-09-254 1 US
5950-00-899-9197 2008-06-155 80 DIBBS
5950-00-899-9197 2008-04-102 55 DIBBS
5950-00-899-9197 2007-08-243 78 DIBBS

Cross Reference | NSN 5950-00-899-9197

Part Number Cage Code Manufacturer
100867 10138 ASTRONAUTICS CORPORATION OF AMERICA
4009 10138 ASTRONAUTICS CORPORATION OF AMERICA
50758 64053 COILTRON INC
BC4009 89870 BERKSHIRE TRANSFORMER
C5073 72149 ELECTRONIC TRANSFORMER CORP.
SA8999-197 54991 ASCHBACHER AND ASSOCIATES INC
TM-341 95970 MTE CORP MILWAUKEE TRANSFORMER CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-899-9197

Technical Data | NSN 5950-00-899-9197

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 40.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 30.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD CORE AND THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 1 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.620 INCHES MAXIMUM
BODY OUTSIDE DIAMETER 1.500 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 10138
DESIGN CONTROL REFERENCE 100867

Restrictions/Controls & Freight Information | NSN 5950-00-899-9197

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-899-9197

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each