Product Details | POWER TRANSFORMER

5950-00-896-3353 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: BF9529, BF95-29, 580R072H01, 7341, 7500225000, 750-0225-000, 9501834400, 950-1834-400, 5950-00-896-3353, 00-896-3353, 5950008963353, 008963353

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 03 FEB 1967 00-896-3353

Cross Reference | NSN 5950-00-896-3353

Part Number Cage Code Manufacturer
580R072H01 18245 ROCKWELL INTERNATIONAL CORP WEST VIRGINIA ELECTRONICS
580R072H01 97942 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS
7341 05614 ALTEC LANSING CORP SOUND PRODUCTS DIV
750-0225-000 10581 STANDEX ELECTRONICS INC.
750-0225-000 21908 NCR CORP POWER SYSTEMS DIV
950-1834-400 27777 L-3 COMMUNICATIONS CORPORATION DBA WARRIOR SYSTEMS DIVISION
BF95-29 59523 NORTH ERIE ELECTRONICS, INC DBA WESTERN RESERVE TOOL MACHINE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-896-3353

Technical Data | NSN 5950-00-896-3353

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE 195.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 18.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 380.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.600 INCHES NOMINAL
BODY HEIGHT 1.650 INCHES NOMINAL
BODY WIDTH 1.850 INCHES NOMINAL
MANUFACTURERS CODE 97942
DESIGN CONTROL REFERENCE 580R072H01

Restrictions/Controls & Freight Information | NSN 5950-00-896-3353

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-896-3353

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeBFSU:F-4 (PHANTOM II)
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each