Product Details | AUDIO FREQUENCY TRANSFORMER

5950-00-890-9485 A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.

Part Alternates: PCT30, 10114681, 101-1468-1, 5950-00-890-9485, 00-890-9485, 5950008909485, 008909485

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 17 APR 1968 00-890-9485

Cross Reference | NSN 5950-00-890-9485

Part Number Cage Code Manufacturer
101-1468-1 12868 BEHLMAN ELECTRONICS, INC. DIV BEHLMAN ELECTRONICS, INC
PCT30 80089 EMERSON ELECTRIC CO WHITE-RODGERS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-890-9485

Technical Data | NSN 5950-00-890-9485

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 1.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
IMPEDANCE RATING IN OHMS 10000.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY 1200.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
MAXIMUM TRANSFORMER POWER RATING 75.0 MILLIWATTS SINGLE COMPONENT
PRIMARY TO SECONDARY TURN RATIO 1 TO 2-55/64 SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.405 INCHES NOMINAL
BODY HEIGHT 0.460 INCHES NOMINAL
BODY WIDTH 0.305 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER FUNCTION LINE

Restrictions/Controls & Freight Information | NSN 5950-00-890-9485

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-890-9485

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each