NSN 5950-00-884-0172 91001748, 9100-1748, 00-884-0172
Product Details | POWER TRANSFORMER
5950-00-884-0172 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 91001748, 9100-1748, 5950-00-884-0172, 00-884-0172, 5950008840172, 008840172
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 17 NOV 1967 | 00-884-0172 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-884-0172
Technical Data | NSN 5950-00-884-0172
Characteristic | Specifications |
---|---|
(NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 305.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 290.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 115.00 AC VOLTS NOMINAL AND 230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 110.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 85.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | BRACKET SINGLE GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 3.250 INCHES MAXIMUM |
BODY HEIGHT | 1.940 INCHES MAXIMUM |
BODY WIDTH | 2.250 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
(NON-CORE DATA) CUBIC MEASURE | 14.2 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5950-00-884-0172
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | SG | 403 SCMS/GUED 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-884-0172
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | T | Other Electronics Equipment |
Weapons Systems/End Item or Homogeneous Group | TD | Test Equip |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |