NSN 5950-00-866-0947 BH8306, 00-866-0947, 008660947
Product Details | POWER TRANSFORMER
5950-00-866-0947 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: BH8306, 5950-00-866-0947, 00-866-0947, 5950008660947, 008660947
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 25 OCT 1967 | 00-866-0947 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-00-866-0947
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5950-00-866-0947 | 2009-04-114 | 3 | DIBBS |
Cross Reference | NSN 5950-00-866-0947
Part Number | Cage Code | Manufacturer |
---|---|---|
BH8306 | 98869 | HOWELL INSTRUMENTS, INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-866-0947
Technical Data | NSN 5950-00-866-0947
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 14 TAB, SOLDER LUG |
(NON-CORE DATA) WINDING TAP LOCATION | TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 18.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 20.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL AND 48.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 20.00 AC VOLTS NOMINAL AND 135.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 40.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 350.0 HERTZ MINIMUM AND 450.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.310 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.680 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 4.310 INCHES NOMINAL |
BODY HEIGHT | 3.500 INCHES NOMINAL |
BODY WIDTH | 3.680 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
MANUFACTURERS CODE | 98869 |
DESIGN CONTROL REFERENCE | BH8306 |
Restrictions/Controls & Freight Information | NSN 5950-00-866-0947
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | SG | 403 SCMS/GUED 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-866-0947
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | JX | TG:AIRCRAFT MAINTENANCE EQUIPMENT |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |