Product Details | POWER TRANSFORMER

5950-00-862-0002 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 10525910, 5950-00-862-0002, 00-862-0002, 5950008620002, 008620002

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-862-0002

Cross Reference | NSN 5950-00-862-0002

Part Number Cage Code Manufacturer
10525910 19200 US ARMY ARDEC RDECOM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-862-0002

Technical Data | NSN 5950-00-862-0002

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 17 SOLDER STUD
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 1ST PRIMARY INPUT MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 3RD SECONDARY MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE 208.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY INPUT 15.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 24.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 20.60 AC VOLTS NOMINAL SINGLE COMPONENT 5TH SECONDARY
WINDING OPERATING CURRENT 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST PRIMARY INPUT 770.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY 640.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY 1.7 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY 960.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 5TH SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL ALL COMPONENTS
WINDING SHIELDING METHOD CORE GROUNDED AND BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP TWO PHASE TO TWO PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 3B SINGLE GROUP
(NON-CORE DATA) THREAD LENGTH 0.250 INCHES NOMINAL SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 3.900 INCHES NOMINAL
OVERALL HEIGHT 2.625 INCHES NOMINAL
FEATURES PROVIDED SPECIAL MARKING
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES 10000 FT MAX ALTITUDE
MANUFACTURERS CODE 19200
DESIGN CONTROL REFERENCE 10525910

Restrictions/Controls & Freight Information | NSN 5950-00-862-0002

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-862-0002

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code1Combat Essential End Item. End item equipments whose availability in a combat ready condition is essential for execution of the combat and training missions of the command.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each