Product Details | POWER TRANSFORMER

5950-00-824-9761 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: SA1327B, LH504, 1243014P1, 5950-00-824-9761, 00-824-9761, 5950008249761, 008249761

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 16 AUG 1967 00-824-9761

Cross Reference | NSN 5950-00-824-9761

Part Number Cage Code Manufacturer
1243014P1 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
LH504 51181 KEYTRONICS, INC. DIV API TECHNOLOGIES - EIS DIVISION
SA1327B 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-824-9761

Technical Data | NSN 5950-00-824-9761

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 13 SOLDER STUD
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE 7.70 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 300.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 175.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 5.00 AC VOLTS NOMINAL AND 19.00 AC VOLTS NOMINAL AND 43.00 AC VOLTS NOMINAL AND 48.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 1.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 3.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 2.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.500 INCHES NOMINAL
BODY HEIGHT 1.750 INCHES NOMINAL
BODY WIDTH 2.500 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-824-9761

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-824-9761

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each