Product Details | RADIO FREQUENCY COIL

5950-00-811-0117 An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.

Part Alternates: 3687321, 368732-1, 5950-00-811-0117, 00-811-0117, 5950008110117, 008110117

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 22 MAR 1968 00-811-0117

Cross Reference | NSN 5950-00-811-0117

Part Number Cage Code Manufacturer
368732-1 37695 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-811-0117

Technical Data | NSN 5950-00-811-0117

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
COIL FORM TYPE AIR WOUND SINGLE COMPONENT
MOUNTING METHOD SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 1 SINGLE GROUP
INCLOSURE TYPE OPEN
BODY LENGTH 0.180 INCHES NOMINAL
OVERALL LENGTH 1.680 INCHES NOMINAL
MANUFACTURERS CODE 37695
DESIGN CONTROL REFERENCE 368732-1

Restrictions/Controls & Freight Information | NSN 5950-00-811-0117

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-811-0117

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each