NSN 5950-00-773-8346 SMB6506806, SM-B-650680-6, 10243466-2
Product Details | RADIO FREQUENCY COIL
5950-00-773-8346 An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.
Part Alternates: SMB6506806, SM-B-650680-6, 10243466-2, 3201186, 320118-6, 558-1505-06-00-00, 5950-00-773-8346, 00-773-8346, 5950007738346, 5581505060000, 102434662, 007738346
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1960 | 00-773-8346 | 06338 ( COIL, RADIO FREQUENCY ) |
Cross Reference | NSN 5950-00-773-8346
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-773-8346
Technical Data | NSN 5950-00-773-8346
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
RATING METHOD | ELECTRICAL AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |
TURN QUANTITY | 52 SINGLE COMPONENT SINGLE WINDING |
WINDING CONDUCTOR SIZE | 0.00708 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
WINDING OPERATING CURRENT | 50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
DC RESISTANCE RATING IN OHMS | 1.500 SINGLE COMPONENT SINGLE WINDING |
INDUCTANCE RATING | 14.50 MICROHENRIES MINIMUM AND 33.00 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |
QUALITY FACTOR | 55 MINIMUM AND 90 MAXIMUM SINGLE COMPONENT SINGLE WINDING |
(NON-CORE DATA) FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES | 2.5 MEGAHERTZ SINGLE COMPONENT SINGLE WINDING |
COIL FORM TYPE | HOLLOW SINGLE COMPONENT |
CORE CONSTRUCTION | POWDERED SINGLE COMPONENT |
ADJUSTMENT METHOD AND QUANTITY | 1 ADJUSTABLE CORE SINGLE COMPONENT |
ADJUSTMENT DEVICE DRIVE TYPE | SHAFT SINGLE COMPONENT |
MOUNTING METHOD | THREADED BUSHING SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 28 SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2A SINGLE GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 0.500 INCHES NOMINAL |
OVERALL LENGTH | 1.497 INCHES NOMINAL |
OVERALL DIAMETER | 0.438 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
III MAXIMUM OPERATING TEMP | 145.0 DEG CELSIUS |
MANUFACTURERS CODE | 80249 |
DESIGN CONTROL REFERENCE | 320118-6 |
Restrictions/Controls & Freight Information | NSN 5950-00-773-8346
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-773-8346
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | R | Tactical and Strategic Communications |
Weapons Systems/End Item or Homogeneous Group | RZ | AN/TRC-170 (V) 2 & 3 TROPO, AN/TRC-175C (BLOS) |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |