Product Details | POWER TRANSFORMER

5950-00-605-9641 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 9T56Y2922, 5950-00-605-9641, 00-605-9641, 5950006059641, 006059641

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 25 JAN 1975 00-605-9641

Cross Reference | NSN 5950-00-605-9641

Part Number Cage Code Manufacturer
9T56Y2922 03512 GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-605-9641

Technical Data | NSN 5950-00-605-9641

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 8 TERMINAL BLOCK W/SCREWS
WINDING OPERATING VOLTAGE 240.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY 120.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 480.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY 240.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING 50.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY 50.0 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY
FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING SLOT WIDTH 0.21875 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.40625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE PARTIALLY INCLOSED, HALF SHELL
BODY LENGTH 4.125 INCHES NOMINAL
OVERALL HEIGHT 3.000 INCHES NOMINAL
OVERALL WIDTH 3.1875 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-605-9641

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information