Product Details | POWER TRANSFORMER

5950-00-538-2781 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 12160A, 5950-00-538-2781, 00-538-2781, 5950005382781, 005382781

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-538-2781

Cross Reference | NSN 5950-00-538-2781

Part Number Cage Code Manufacturer
12160A 80089 EMERSON ELECTRIC CO WHITE-RODGERS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-538-2781

Technical Data | NSN 5950-00-538-2781

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 WIRE LEAD
WINDING OPERATING VOLTAGE 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 0.6 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 6 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.270 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.688 INCHES NOMINAL
BODY HEIGHT 3.500 INCHES NOMINAL
BODY WIDTH 2.812 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 80089
DESIGN CONTROL REFERENCE 12160A

Restrictions/Controls & Freight Information | NSN 5950-00-538-2781

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information