NSN 5950-00-437-4083 HI1301, HI-1301, T9505
Product Details | POWER TRANSFORMER
5950-00-437-4083 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: HI1301, HI-1301, T9505, 0073019P1, 0073-019P1, 10017, 40803, 9505, 5950-00-437-4083, 00-437-4083, 5950004374083, 004374083
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 29 AUG 1969 | 00-437-4083 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-00-437-4083
Part Number | Request Date | QTY | Origin |
---|---|---|---|
10017 | 2019-02-53 | 10 | US |
Cross Reference | NSN 5950-00-437-4083
Part Number | Cage Code | Manufacturer |
---|---|---|
0073-019P1 | 06351 | MICROWAVE ENGINEERING CORPORATION |
0073-019P1 | 99380 | SIERRA NETWORKS INC SIERRACOM DIV |
10017 | 10581 | STANDEX ELECTRONICS INC. |
40803 | 22558 | COAST/ADVANCED CHIP MAGNETICS, INC. DBA COAST/A C M |
9505 | 81564 | ARTTED CO INC |
HI-1301 | 56936 | GOODWILL ENGINEERING DESIGNS |
T9505 | 80495 | ANDERSON AIRMOTIVE PRODUCTS COMPANY, INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-437-4083
Technical Data | NSN 5950-00-437-4083
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 8 PIN |
WINDING OPERATING VOLTAGE | 11.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 0.00 AC VOLTS MINIMUM AND 2.50 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO TWO PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE AND TERMINAL SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY HEIGHT | 0.625 INCHES MAXIMUM |
OVERALL LENGTH | 2.000 INCHES MAXIMUM |
OVERALL WIDTH | 1.000 INCHES MAXIMUM |
FEATURES PROVIDED | TINNED WIRE LEADS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
III TRANSFORMER WINDING CONNECTION TYPE | SCOTT |
III MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5950-00-437-4083
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-437-4083
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |