Product Details | POWER TRANSFORMER

5950-00-421-9744 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: BTC14462, BTC-14462, C16769, L504000359, 1569243, 5950-00-421-9744, 00-421-9744, 5950004219744, 004219744

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 21 DEC 1970 00-421-9744

Cross Reference | NSN 5950-00-421-9744

Part Number Cage Code Manufacturer
1569243 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
BTC-14462 89870 BERKSHIRE TRANSFORMER
C16769 72149 ELECTRONIC TRANSFORMER CORP.
L504000359 36090 LOCKHEED MARTIN LIBRASCOPE CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-421-9744

Technical Data | NSN 5950-00-421-9744

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 10 TURRET
(NON-CORE DATA) WINDING TAP LOCATION TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY TAP W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE 8.25 AC VOLTS NOMINAL AND 12.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 8.25 AC VOLTS NOMINAL AND 12.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 108.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 122.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.677 INCHES MINIMUM AND 1.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.427 INCHES MINIMUM AND 1.447 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
OVERALL LENGTH 2.312 INCHES MAXIMUM
OVERALL HEIGHT 3.545 INCHES MAXIMUM
OVERALL WIDTH 2.062 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 10001-1569243 DRAWING
III MAXIMUM OPERATING TEMP 70.0 DEG CELSIUS
(NON-CORE DATA) CUBIC MEASURE 16.9 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5950-00-421-9744

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-421-9744

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each