Product Details | POWER TRANSFORMER

5950-00-251-1693 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: T7611798P131, 5950-00-251-1693, 00-251-1693, 5950002511693, 002511693

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-251-1693

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-251-1693

Technical Data | NSN 5950-00-251-1693

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 8 THREADED STUD
(NON-CORE DATA) WINDING TAP LOCATION TAP W/O CENTER TAP SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE 15.00 AC VOLTS NOMINAL OR 315.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 20.00 AC VOLTS NOMINAL OR 260.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.3 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
BODY LENGTH 4.312 INCHES NOMINAL
BODY HEIGHT 6.562 INCHES NOMINAL
BODY WIDTH 4.000 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-251-1693

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information