NSN 5950-00-250-7508 S24332, TR1179D, 00-250-7508
Product Details | PULSE TRANSFORMER
5950-00-250-7508 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.
Part Alternates: S24332, TR1179D, 5950-00-250-7508, 00-250-7508, 5950002507508, 002507508
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-250-7508 | 00208 ( TRANSFORMER, PULSE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-250-7508
Related Products | NSN 5950-00-250-7508
Technical Data | NSN 5950-00-250-7508
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 6 BINDING POST |
INDUCTANCE RATING | 12.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
PRIMARY TO SECONDARY TURN RATIO | 1.55 TO 1 TO 3.55 TO 1 SINGLE COMPONENT |
(NON-CORE DATA) PULSE DURATION IN MICROSECONDS | 1.000 SINGLE COMPONENT |
PULSE REPETITION RATE | 4.0 KILOHERTZ SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 1.500 INCHES NOMINAL |
BODY HEIGHT | 2.250 INCHES NOMINAL |
BODY WIDTH | 1.500 INCHES NOMINAL |
OVERALL HEIGHT | 2.312 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
MANUFACTURERS CODE | 72149 |
DESIGN CONTROL REFERENCE | S24332 |
Restrictions/Controls & Freight Information | NSN 5950-00-250-7508
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |