Product Details | POWER TRANSFORMER

5950-00-232-7286 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 114559PC1, 5950-00-232-7286, 00-232-7286, 5950002327286, 002327286

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 02 NOV 1970 00-232-7286

Cross Reference | NSN 5950-00-232-7286

Part Number Cage Code Manufacturer
114559PC1 4N727 GE AVIATION SYSTEMS LLC DBA GE AVIATION
114559PC1 62793 BFM ENERGY PRODUCTS CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-232-7286

Technical Data | NSN 5950-00-232-7286

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 500.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING 230.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
BODY LENGTH 4.500 INCHES NOMINAL
BODY HEIGHT 3.880 INCHES NOMINAL
BODY WIDTH 3.620 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
CRITICALITY CODE JUSTIFICATION ZZZY
MANUFACTURERS CODE 62793
DESIGN CONTROL REFERENCE 114559PC1

Restrictions/Controls & Freight Information | NSN 5950-00-232-7286

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:FMunitions List Item or Commerce Control List Item. Demilitarization required. Demilitarization Instructions to be furnished by the Item/Technical Manager.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code HX Navy ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-232-7286

Category Code Description
Cognizance Codes1HConsumable material assigned to NAVICP MECH for inventory management
Naval Inventory Control Point, Mechanicsburg
Special Material IDX3Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4.
Issue Repair, or RequisitionBLSubmit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipments.
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityMMedium Demand Velocity Items (consumables)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each