NSN 5950-00-116-3305 C2224, PEI 8863, PEI8863
Product Details | POWER TRANSFORMER
5950-00-116-3305 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: C2224, PEI 8863, PEI8863, PTCT19088, PTC-T19088, R104192, RX00349, RX349, T130266, 441351, 44135-1, 5144961, 514496-1, 8000256, 800025-6, 5950-00-116-3305, 00-116-3305, 5950001163305, 001163305
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 11 FEB 1973 | 00-116-3305 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-00-116-3305
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5950-00-116-3305 | 2024-04-99 | 90 | DIBBS |
5950-00-116-3305 | 2024-03-81 | 28 | DIBBS |
5950-00-116-3305 | 2024-01-30 | 48 | DIBBS |
5950-00-116-3305 | 2024-01-21 | 20 | DIBBS |
5950-00-116-3305 | 2022-11-331 | 9 | DIBBS |
5950-00-116-3305 | 2022-11-306 | 55 | DIBBS |
5950-00-116-3305 | 2022-10-291 | 55 | DIBBS |
5950-00-116-3305 | 2021-11-312 | 51 | DIBBS |
5950-00-116-3305 | 2021-10-297 | 51 | DIBBS |
5950-00-116-3305 | 2020-11-310 | 65 | DIBBS |
5950-00-116-3305 | 2020-10-302 | 18 | DIBBS |
5950-00-116-3305 | 2019-11-307 | 120 | DIBBS |
5950-00-116-3305 | 2019-10-294 | 64 | DIBBS |
5950-00-116-3305 | 2019-04-105 | 41 | DIBBS |
5950-00-116-3305 | 2019-03-76 | 5 | DIBBS |
5950-00-116-3305 | 2016-12-351 | 1 | DIBBS-RFPs |
5950-00-116-3305 | 2016-12-340 | 95 | DIBBS |
5950-00-116-3305 | 2015-08-237 | 94 | DIBBS |
5950-00-116-3305 | 2015-04-91 | 52 | DIBBS |
5950-00-116-3305 | 2014-03-82 | 89 | DIBBS |
5950-00-116-3305 | 2012-09-268 | 77 | DIBBS |
5950-00-116-3305 | 2012-08-226 | 88 | DIBBS |
5950-00-116-3305 | 2012-08-226 | 92 | DIBBS |
5950-00-116-3305 | 2012-08-226 | 65 | DIBBS |
5950-00-116-3305 | 2012-08-215 | 91 | DIBBS |
5144961 | 2011-12-336 | 20 | United States |
Cross Reference | NSN 5950-00-116-3305
Part Number | Cage Code | Manufacturer |
---|---|---|
44135-1 | 22558 | COAST/ADVANCED CHIP MAGNETICS, INC. DBA COAST/A C M |
514496-1 | 04620 | RAYCO ELECTRONIC MFG.INC. |
514496-1 | 36334 | INDAL TECHNOLOGIES INC |
514496-1 | 52115 | L. L. ROWE COMPANY |
514496-1 | 57626 | COMSACO, INC. |
514496-1 | 59533 | MAGNETIC DESIGN LABS, INC. |
514496-1 | 80020 | NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION CODE 4.8.8.0.0.B BLDG 148-2 |
514496-1 | 88829 | TABET MANUFACTURING COMPANY, INC. |
800025-6 | 44291 | U.S. PIONEER, L.L.C. DBA U.S. PIONEER |
800025-6 | 58475 | WESTWOOD CORPORATION DBA NMP DIVISION |
800025-6 | 76714 | O-Z/GEDNEY CO NELSON FIRESTOP PRODUCTS DIV A UNIT OF GENERAL |
C2224 | 72149 | ELECTRONIC TRANSFORMER CORP. |
PEI 8863 | 13483 | PRECISION ELECTRONICS, INC. |
PTC-T19088 | 05853 | PTC TRANSFORMERS |
R104192 | 98330 | OECO, LLC |
RX00349 | 13619 | EMS DEVELOPMENT CORPORATION |
RX349 | 13619 | EMS DEVELOPMENT CORPORATION |
T130266 | 77096 | PALMER ELECTRIC CO DIV TABET MFG CO INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-116-3305
Technical Data | NSN 5950-00-116-3305
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 7 WIRE LEAD |
(NON-CORE DATA) WINDING TAP LOCATION | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 6.60 AC VOLTS NOMINAL AND 12.50 AC VOLTS NOMINAL AND 30.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY 150.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 200.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY 200.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.937 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
OVERALL LENGTH | 4.438 INCHES NOMINAL |
OVERALL HEIGHT | 4.062 INCHES NOMINAL |
OVERALL WIDTH | 4.500 INCHES NOMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
Restrictions/Controls & Freight Information | NSN 5950-00-116-3305
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-116-3305
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |