Product Details | POWER TRANSFORMER

5950-00-054-1869 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 9T21A9104, 5950-00-054-1869, 00-054-1869, 5950000541869, 000541869

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-054-1869

Cross Reference | NSN 5950-00-054-1869

Part Number Cage Code Manufacturer
9T21A9104 24446 GENERAL ELECTRIC CO
9T21A9104 95018 GENERAL ELECTRIC CO TRANSFORMER DIVISION OF

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-054-1869

Technical Data | NSN 5950-00-054-1869

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 WIRE LEAD W/CLAMP
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 25.0 KILOVOLT-AMPERE SINGLE COMPONENT
WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 28.188 INCHES NOMINAL
OVERALL HEIGHT 10.062 INCHES NOMINAL
OVERALL WIDTH 11.625 INCHES NOMINAL
III COOLING METHOD SELF-COOLED
III COOLING TYPE FINS
MANUFACTURERS CODE 95018
DESIGN CONTROL REFERENCE 9T21A9104

Restrictions/Controls & Freight Information | NSN 5950-00-054-1869

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable