Product Details | POWER TRANSFORMER

5950-00-045-1813 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: TW60569, 1897646, 5950-00-045-1813, 00-045-1813, 5950000451813, 000451813

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-045-1813

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-045-1813

Technical Data | NSN 5950-00-045-1813

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 TURRET
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING 6.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 40 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 1.062 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM
OVERALL LENGTH 1.402 INCHES NOMINAL
III MAXIMUM OPERATING TEMP 65.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 2.000 OUNCES
(NON-CORE DATA) CUBIC MEASURE 1.1 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5950-00-045-1813

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information