Product Details | SOLID STATE RELAY

5945-01-480-4961 A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. In lieu of separable contacts and their actuator(s), the switching function is accomplished by means of an arrangement of semiconductors and passive circuit devices. The device is designed to have electrical isolation between control circuit and output circuit. Excludes RELAY, HYBRID.

Part Alternates: AP10902000, AP1090-2000, 5945-01-480-4961, 01-480-4961, 5945014804961, 014804961

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 22 NOV 2000 01-480-4961

Cross Reference | NSN 5945-01-480-4961

Part Number Cage Code Manufacturer
AP1090-2000 53651 EUROTHERM ACTION, INC DBA ACTION INSTRUMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-480-4961

Technical Data | NSN 5945-01-480-4961

Characteristic Specifications
VOLTAGE RATING 10.0 MILLIVOLTS MINIMUM AND 200.0 VOLTS MAXIMUM INPUT
CURRENT RATING 1.00 MILLIAMPERES MINIMUM AND 100.00 MILLIAMPERES MAXIMUM INPUT
TERMINAL TYPE AND QUANTITY 11 PIN
OPERATING TEMP RANGE 32.0 TO 140.0 DEG FAHRENHEIT
OVERALL LENGTH 2.850 INCHES NOMINAL
OVERALL WIDTH 2.050 INCHES NOMINAL
OVERALL HEIGHT 3.500 INCHES NOMINAL
SPECIAL FEATURES 0.62 LBS. WEIGHT; SINGLE/DUAL TRIP (2 SPDT, 5A); FIELD CONFIGURABLE INPUT RANGES FOR DC VOLTAGE AND CURRENT; PROGRAMMABLE HI OR LO SETPOINTS; DYNAMIC DEADBAND PREVENTS FALSE TRIPS; SELECTABLE FAILSAFE/LATCHING OPERATION; LED TRIP INDICATORS; SELECTABLE 120/240VAC OPERATION
III END ITEM IDENTIFICATION WATER SEWAGE TREATMENT PLANT, B/G 15MX3-1.C

Restrictions/Controls & Freight Information | NSN 5945-01-480-4961

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information