NSN 5945-00-884-1508 E31309, 92504, 92710
Product Details | ELECTROMAGNETIC RELAY
5945-00-884-1508 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: E31309, 92504, 92710, 92757, 2538132, 340902, 5945-00-884-1508, 00-884-1508, 5945008841508, 008841508
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 17 NOV 1967 | 00-884-1508 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Cross Reference | NSN 5945-00-884-1508
Part Number | Cage Code | Manufacturer |
---|---|---|
2538132 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
340902 | 56232 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
92504 | 07031 | TEMPO INSTRUMENT INC DEFENSE ELECTRONICS DIV |
92504 | 48313 | B.C. SYSTEMS INC. |
92710 | 07031 | TEMPO INSTRUMENT INC DEFENSE ELECTRONICS DIV |
92710 | 48313 | B.C. SYSTEMS INC. |
92757 | 07031 | TEMPO INSTRUMENT INC DEFENSE ELECTRONICS DIV |
92757 | 48313 | B.C. SYSTEMS INC. |
E31309 | 82227 | VDO CONTROL SYSTEMS INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-884-1508
Related Products | NSN 5945-00-884-1508
Technical Data | NSN 5945-00-884-1508
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
TIME DELAY | 20.00 SECONDS NOMINAL FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.906 INCHES MAXIMUM |
OVERALL WIDTH | 1.891 INCHES MAXIMUM |
OVERALL HEIGHT | 3.469 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.531 INCHES NOMINAL SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL SINGLE MOUNTING FACILITY |
SPECIAL FEATURES | EXTERNAL RESISTOR CONNECTED ACROSS TERMINALS 6 AND 9 |
Restrictions/Controls & Freight Information | NSN 5945-00-884-1508
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-00-884-1508
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |