NSN 5945-00-721-1901 26510B, 26-5-10B, 26510SB
Product Details | THERMAL RELAY
5945-00-721-1901 A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see SWITCH, THERMOSTATIC.
Part Alternates: 26510B, 26-5-10B, 26510SB, 26-5-10SB, 278818, 5945-00-721-1901, 00-721-1901, 5945007211901, 007211901
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-721-1901 | 03883 ( RELAY, THERMAL ) |
Cross Reference | NSN 5945-00-721-1901
Part Number | Cage Code | Manufacturer |
---|---|---|
26-5-10B | 22525 | INSTRUMENTS AND FLIGHT RESEARCH INC. |
26-5-10SB | 03877 | GILBERT ENGINEERING CO INC/INCON SUB OF TRANSITRON ELECTRONIC CORP |
26-5-10SB | 22525 | INSTRUMENTS AND FLIGHT RESEARCH INC. |
26-5-10SB | 57741 | NAULT ROBERT DBA TDR ELECTRONICS |
278818 | 1PQF4 | L-3 COMMUNICATIONS CORPORATION DBA LINK SIMULATION & TRAINING |
278818 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-721-1901
Related Products | NSN 5945-00-721-1901
Technical Data | NSN 5945-00-721-1901
Characteristic | Specifications |
---|---|
CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 230.0 AC |
CONTACT MAXIMUM CURRENT RATING IN AMPS | 3.0 AC |
HEATER VOLTAGE RATING IN VOLTS | 26.5 |
HEATER POWER RATING IN WATTS | 3.5 |
DELAY TIME IN SECONDS | 12.0 FIXED OPERATE NOMINAL |
TERMINAL TYPE AND QUANTITY | 5 PIN |
MOUNTING FACILITY TYPE AND QUANTITY | 1 OCTAL BASE PLUG-IN |
OVERALL LENGTH | 2.000 INCHES NOMINAL |
OVERALL DIAMETER | 1.286 INCHES NOMINAL |
ENVIRONMENTAL PROTECTION | HERMETIC |
Restrictions/Controls & Freight Information | NSN 5945-00-721-1901
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-00-721-1901
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Price Validation | V | The current standard price has been validated.
|
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |