NSN 5945-00-010-8336 D62701, D6270-1, DC10716
Product Details | THERMAL FLASHER
5945-00-010-8336 An item designed to complete, interrupt or change the connections in one or more electrical lighting circuits in accordance with a predetermined time cycle. It is actuated by the effect of heat generated by current passing through its circuit(s). Excludes CONTROL, DIRECTIONAL SIGNAL LIGHT, AUTOMOTIVE, and SWITCH THERMOSTATIC. See also FLASHER, SOLID STATE.
Part Alternates: D62701, D6270-1, DC10716, DC10716A, 10716, 10716A, 32760571, 32-76057-1, 7000311, 70-0031-1, 5945-00-010-8336, 00-010-8336, 5945000108336, 000108336
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 13 MAY 1968 | 00-010-8336 | 08410 ( FLASHER, THERMAL ) |
Cross Reference | NSN 5945-00-010-8336
Part Number | Cage Code | Manufacturer |
---|---|---|
10716 | 07148 | UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP |
10716 | 73030 | HAMILTON SUNDSTRAND CORPORATION |
10716A | 07148 | UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP |
10716A | 73030 | HAMILTON SUNDSTRAND CORPORATION |
32-76057-1 | 76301 | BOEING COMPANY, THE DBA BOEING |
70-0031-1 | 72914 | GRIMES AEROSPACE COMPANY DBA HONEYWELL |
D6270-1 | 72914 | GRIMES AEROSPACE COMPANY DBA HONEYWELL |
DC10716 | 07148 | UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP |
DC10716 | 73030 | HAMILTON SUNDSTRAND CORPORATION |
DC10716A | 07148 | UNITED TECHNOLOGIES CORP HAMILTON SUNDSTRAND CORP |
DC10716A | 73030 | HAMILTON SUNDSTRAND CORPORATION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-010-8336
Related Products | NSN 5945-00-010-8336
Technical Data | NSN 5945-00-010-8336
Characteristic | Specifications |
---|---|
ADJUSTABILITY | NONADJUSTABLE |
FLASHING RATE | 80 PER MINUTE NOMINAL |
DUTY CYCLE | 0.56 SECONDS ON |
ACCURACY IN PERCENT | 15.0 |
FAILURE AUTOMATIC CIRCUIT CONDITION | OFF |
CONTROLLED CIRCUIT QUANTITY | 2 |
ACTUATION TYPE | ELECTROMECHANICAL |
DC VOLTAGE RATING | 24.0 VOLTS MINIMUM AND 29.0 VOLTS MAXIMUM |
TERMINAL QUANTITY | 1 |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
OVERALL LENGTH | 4.500 INCHES NOMINAL |
OVERALL HEIGHT | 2.380 INCHES NOMINAL |
OVERALL WIDTH | 4.500 INCHES NOMINAL |
MOUNTING CONFIGURATION | 4 HOLES 0.257 IN. DIA ON 4.000 IN. BY 4.000 IN. CENTERS |
Restrictions/Controls & Freight Information | NSN 5945-00-010-8336
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-00-010-8336
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |