Product Details | THERMAL RELAY

5945-00-008-4254 A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see SWITCH, THERMOSTATIC.

Part Alternates: GS5131, 2805554P2, 5945-00-008-4254, 00-008-4254, 5945000084254, 000084254

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 21 JUL 1972 00-008-4254

Cross Reference | NSN 5945-00-008-4254

Part Number Cage Code Manufacturer
2805554P2 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
2805554P2 93929 SPX CORPORATION DBA RADIODETECTION
GS5131 93929 SPX CORPORATION DBA RADIODETECTION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-008-4254

Technical Data | NSN 5945-00-008-4254

Characteristic Specifications
CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY OPEN
CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 250.0 AC AND 32.0 DC
CONTACT MAXIMUM CURRENT RATING IN AMPS 2.0 AC OR 1.0 DC
HEATER VOLTAGE RATING IN VOLTS 0.88
DELAY TIME IN SECONDS 300.0 FIXED RELEASE MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
OVERALL LENGTH 1.380 INCHES NOMINAL
OVERALL WIDTH 1.000 INCHES NOMINAL
OVERALL HEIGHT 2.650 INCHES NOMINAL
ENVIRONMENTAL PROTECTION HERMETIC
SPECIAL FEATURES TWO 0.130 IN. DIA MTG HOLES SPACED 1.125 IN. C TO C

Restrictions/Controls & Freight Information | NSN 5945-00-008-4254

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-008-4254

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each