Product Details | TERMINAL BOARD

5940-01-021-2538 An item consisting of insulating material, which is specifically designed to have fastened thereon, or on which are fastened terminal(s), such as screws, solder lugs, solder studs, solderless connectors, clips, and the like. It is usually used for junctions or terminations of wire or cable assemblies. It does not include items as defined above with parts, such as resistors and capacitors mounted thereon. Do not use if a more specific name exists, such as FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (as modified); CONNECTOR (as modified). Excludes TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; and CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. For items having printed electrical conductor paths, see PRINTED WIRING BOARD.

Part Alternates: 649 XP 10, 64910, 649-10, 64910XP, 649-10-XP, 649XP10, 5940-01-021-2538, 01-021-2538, 5940010212538, 010212538

Electrical and Electronic Equipment Components | Lugs, Terminals, and Terminal Strips

Supply Group (FSG) NSN Assign. NIIN
59 11 MAY 1976 01-021-2538

Drawings & Photos | NSN 5940-01-021-2538


Cross Reference | NSN 5940-01-021-2538

Part Number Cage Code Manufacturer
649 XP 10 26405 MARATHON SPECIAL PRODUCTS CORPORATION
649-10 26405 MARATHON SPECIAL PRODUCTS CORPORATION
649-10 83330 DIALIGHT CORPORATION
649-10-XP 83330 DIALIGHT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5940-01-021-2538

Technical Data | NSN 5940-01-021-2538

Characteristic Specifications
MATERIAL PLASTIC PHENOLIC BOARD COPPER ALLOY TERMINALS
SURFACE TREATMENT NICKEL TERMINALS
BODY STYLE A22 STRIP
BOARD OVERALL LENGTH 2.562 INCHES
BOARD OVERALL HEIGHT 0.688 INCHES
BOARD HEIGHT EXCLUDING TERMINALS 0.312 INCHES
BOARD THICKNESS 0.078 INCHES
NONFEEDTHRU TERMINAL TYPE 145 SINGLE
NONFEEDTHRU TERMINAL QUANTITY 10 SINGLE
BOARD CONSTRUCTION SOLID CONSTRUCTION
MOUNTING FACILITY TYPE AND QUANTITY 1 FRICTION
CURRENT RATING IN AMPS 5.0
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS 1000.0

Restrictions/Controls & Freight Information | NSN 5940-01-021-2538

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061045 BOARDS PRINTED CIRCUIT ELEC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5940-01-021-2538

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code2Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items.
Materiel Management CodeGGeneral Property MaterielDefense Supply Center Richmond (DSCR)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each