Product Details | CONNECTOR ADAPTER

5935-01-610-0966 An adapter with electrical contacts which provides facilities for joining two or more electrical connectors, whose design or function will not normally warrant their junction. It is not designed for permanent attachment to a cable, cord, coaxial line, or wire. The physical shape of an electrical connector should not be the determining factor of its name. Tee, angle, straight, and Y-shaped adapters are all ADAPTER, CONNECTOR. Excludes ADAPTER, CONNECTOR TO LAMPBASE; ADAPTER, LAMPHOLDER TO CONNECTOR; ADAPTER (1), CABLE CLAMP TO CONNECTOR; and ADAPTER, LAMPHOLDER. For items designed as a mechanical connection between an electrical conduit and an electrical connector, see ADAPTER (1), ELECTRICAL CONDUIT.

Part Alternates: 28815 , 5935-01-610-0966, 01-610-0966, 5935016100966, 016100966

Electrical and Electronic Equipment Components | Connectors, Electrical

Supply Group (FSG) NSN Assign. NIIN
59 2012222 01-610-0966

Cross Reference | NSN 5935-01-610-0966

Part Number Cage Code Manufacturer
28815 03877 GILBERT ENGINEERING CO INC/INCON SUB OF TRANSITRON ELECTRONIC CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5935-01-610-0966

Technical Data | NSN 5935-01-610-0966

Characteristic Specifications
BODY STYLE STRAIGHT SHAPE, FIBER OPTIC
OVERALL LENGTH 0.650 INCHES NOMINAL
OVERALL HEIGHT 0.861 INCHES NOMINAL
OVERALL WIDTH 0.359 INCHES NOMINAL
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.520 INCHES NOMINAL
SPECIAL FEATURES STAINLESS STEEL SPRING LOCATED INSIDE CONNECTOR.
III PRECIOUS MATERIAL GOLD
III END ITEM IDENTIFICATION GLOBALHAWK, ASIP
III PART NAME ASSIGNED BY CONTROLLING AGENCY GMS FLOAT MOUNT TO SMA JACK

Restrictions/Controls & Freight Information | NSN 5935-01-610-0966

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061680 ELEC WIRING PLUGS ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code GX HQ Defense Logistics Agency, Enterprise Business
Systems
Fort Belvoir, VA 22060
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5935-01-610-0966

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each