Product Details | STANDARD 1.20 MISMATCH

5935-01-571-0147

Part Alternates: 2561C, 5935-01-571-0147, 01-571-0147, 5935015710147, 015710147

Electrical and Electronic Equipment Components | Connectors, Electrical

Supply Group (FSG) NSN Assign. NIIN
59 22 JAN 2009 01-571-0147

Demand History | NSN 5935-01-571-0147

Part Number Request Date QTY Origin
2561C 2024-09-256 5 DIBBS
2561C 2021-01-14 8 DIBBS
2561C 2021-01-03 8 DIBBS
5935-01-571-0147 2015-07-211 14 DIBBS
5935-01-571-0147 2011-09-271 9 DIBBS
5935-01-571-0147 2011-08-213 6 DIBBS
5935-01-571-0147 2011-07-192 1 DIBBS
5935-01-571-0147 2010-12-348 3 DIBBS
5935-01-571-0147 2010-12-347 3 DIBBS

Cross Reference | NSN 5935-01-571-0147

Part Number Cage Code Manufacturer
2561C 13047 MAURY MICROWAVE, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5935-01-571-0147

Technical Data | NSN 5935-01-571-0147

Characteristic Specifications
GENERAL CHARACTERISTICS ITEM DESCRIPTION PRECISION STANDARD MISMATCHES ARE FIXED COAXIAL TERMINATIONS WHICH ARE USED TO INTRODUCE A KNOWN VSWR INTO A 50 OHM TRANSMISSION SYSTEM,CAN BE USED TO CALIBRATE SWEPT REFLECTOMETERS, VERIFY NETWORK ANALYZER CALIBRATION, ESTABLISH IMPEDANCE REFERENCES IN TDR MEASUREMENTS, ECT
SPECIAL FEATURES NOMINAL VSWR: 1.20;ACCURACY: DC-8.0 GHZ,PLUS OR MINUS 0.06,8.0-12.4 GHZ,PLUS OR MINUS 0.07,12.4-18.0 GHZ,PLUS OR MINUS 0.10;RESISTANCE (OHMS): 41.7
END ITEM IDENTIFICATION 4940-01-551-2884;MAINTENANCE FACILITY, TRANSPORTABLE

Restrictions/Controls & Freight Information | NSN 5935-01-571-0147

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061680 ELEC WIRING PLUGS ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code PA Marine Corps Logistics Base
Albany, GA 31704-1128
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5935-01-571-0147

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Operational Test Code3All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each