NSN 5935-01-398-7236 D38999/20F-D05SN, D3899920FD05SN, MIL-C-38999/20
Product Details | ELECTRICAL RECEPTACLE CONNECTOR
5935-01-398-7236 An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), PRINTED WIRING BOARD, or the like for convenience in joining with another electrical connector(s) or PRINTED WIRING BOARD. It is designed to be mounted on a bulkhead, chassis, panel, wall, PRINTED WIRING BOARD, or the like. Excludes LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (as modified) and SOCKET, PLUG-IN ELECTRONIC COMPONENTS. See also WIRING HARNESS (as modified) and CABLE ASSEMBLY (as modified). For items with termination wires of more than four inches in length, see LEAD ASSEMBLY, ELECTRICAL. For items without inserts, see SHELL, ELECTRICAL CONNECTOR.
Part Alternates: D38999/20F-D05SN, D3899920FD05SN, MIL-C-38999/20, MILC3899920, 5935-01-398-7236, 01-398-7236, 5935013987236, 013987236
Electrical and Electronic Equipment Components | Connectors, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 08 NOV 1994 | 01-398-7236 | 15093 ( CONNECTOR, RECEPTACLE, ELECTRICAL ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5935-01-398-7236
Technical Data | NSN 5935-01-398-7236
Characteristic | Specifications |
---|---|
BODY STYLE | 3G STRAIGHT SHAPE, EXTERNAL COUPLING |
OVERALL LENGTH | 31.5 MILLIMETERS MAXIMUM |
OVERALL HEIGHT | 23.8 MILLIMETERS NOMINAL |
OVERALL WIDTH | 23.8 MILLIMETERS NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 18.26 MILLIMETERS NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 18.26 MILLIMETERS NOMINAL |
DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 20.9 MILLIMETERS NOMINAL |
MATING END QUANTITY | 1 |
CONTACT POSITION ARRANGEMENT STYLE | AFDY 15-5 SINGLE MATING END |
INCLUDED CONTACT QUANTITY | 5 SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT REMOVABILITY | REMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
INCLUDED CONTACT TYPE | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
TERMINAL TYPE | CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | D38999/20F-D05SN |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-C-38999/20 |
Restrictions/Controls & Freight Information | NSN 5935-01-398-7236
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061680 | ELEC WIRING PLUGS ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | NI | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5935-01-398-7236
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Physical Category Code | 1 | Bin |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |