NSN 5935-01-079-3213 MS17344R20N7P, QWLD06R20N7P, MILC22992
Product Details | ELECTRICAL PLUG CONNECTOR
5935-01-079-3213 An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or PRINTED WIRING BOARD and is not designed to be mounted on a bulkhead, chasses, panel, PRINTED WIRING BOARD, or the like. Excludes JACK, TELEPHONE; JACK, TIP; PLUG, TELEPHONE; PLUG TIP; INSERT, ELECTRICAL CONNECTOR; CONNECTOR BODY (as modified); and SOCKET, PLUG-IN, ELECTRONIC COMPONENTS. See also LEAD ASSEMBLY, ELECTRICAL; WIRING HARNESS (as modified); and CABLE ASSEMBLY (as modified). For items without inserts, see SHELL, ELECTRICAL CONNECTOR.
Part Alternates: MS17344R20N7P, QWLD06R20N7P, MILC22992, MIL-C-22992, 5935-01-079-3213, 01-079-3213, 5935010793213, 010793213
Electrical and Electronic Equipment Components | Connectors, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JUL 1979 | 01-079-3213 | 01938 ( CONNECTOR, PLUG, ELECTRICAL ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5935-01-079-3213
Technical Data | NSN 5935-01-079-3213
Characteristic | Specifications |
---|---|
BODY STYLE | 7A STRAIGHT SHAPE, INTERNAL COUPLING |
OVERALL LENGTH | 1.795 INCHES MAXIMUM |
OVERALL DIAMETER | 1.688 INCHES MAXIMUM |
CONNECTOR LOCKING METHOD | INTERNALLY THREADED COUPLING RING |
THREADED DEVICE TYPE | BACK SHELL AND COUPLING FACILITY |
THREAD SERIES DESIGNATOR | UNEF AND DOUBLE STUB |
NOMINAL THREAD SIZE | 1.250 INCHES AND 1.375 INCHES |
THREAD CLASS | 2A AND 2B |
THREAD QUANTITY PER INCH | 18 AND 10 |
THREAD DIRECTION | LEFT-HAND AND RIGHT-HAND |
SHELL TYPE | SOLID |
SHELL MATERIAL | ALUMINUM ALLOY |
SHELL SURFACE TREATMENT | OXIDE |
SHELL SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-F-14072 E-516 MIL SPEC SINGLE TREATMENT RESPONSE |
POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
INSERT POSITION IN DEG | 0.0 |
MATING END QUANTITY | 1 |
CONTACT POSITION ARRANGEMENT STYLE | AJAE 20-7 SINGLE MATING END |
INSERT MATERIAL | PLASTIC SINGLE MATING END |
INCLUDED CONTACT QUANTITY | 4 SINGLE MATING END 1ST CONTACT GROUPING 4 SINGLE MATING END 2ND CONTACT GROUPING |
CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
INCLUDED CONTACT TYPE | ROUND PIN SINGLE MATING END ALL CONTACT GROUPINGS |
CONTACT MAXIMUM CURRENT RATING IN AMPS | 22.0 SINGLE MATING END ALL CONTACT GROUPINGS |
CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 500.0 SINGLE MATING END 1ST CONTACT GROUPING 900.0 SINGLE MATING END 2ND CONTACT GROUPING |
CONTACT MAXIMUM DC VOLTAGE RATING IN VOLTS | 700.0 SINGLE MATING END 1ST CONTACT GROUPING 1250.0 SINGLE MATING END 2ND CONTACT GROUPING |
CONTACT MATERIAL | COPPER ALLOY SINGLE MATING END ALL CONTACT GROUPINGS |
CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END ALL CONTACT GROUPINGS |
CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-G-45204 TY 1,CL 1 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END ALL CONTACT GROUPINGS |
TERMINAL TYPE | SOLDER WELL SINGLE MATING END ALL CONTACT GROUPINGS |
TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND THERMAL SHOCK RESISTANT AND VIBRATION RESISTANT |
TEST DATA DOCUMENT | 81349-MIL-C-22992 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 96906-MS17344 GOVERNMENT STANDARD |
Restrictions/Controls & Freight Information | NSN 5935-01-079-3213
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | G | Item contains gold |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061680 | ELEC WIRING PLUGS ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5935-01-079-3213
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | R | Tactical and Strategic Communications |
Weapons Systems/End Item or Homogeneous Group | RV | MULTI-BAND TACSAT |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |