Product Details | ELECTRICAL PLUG CONNECTOR

5935-00-879-5366 An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or PRINTED WIRING BOARD and is not designed to be mounted on a bulkhead, chasses, panel, PRINTED WIRING BOARD, or the like. Excludes JACK, TELEPHONE; JACK, TIP; PLUG, TELEPHONE; PLUG TIP; INSERT, ELECTRICAL CONNECTOR; CONNECTOR BODY (as modified); and SOCKET, PLUG-IN, ELECTRONIC COMPONENTS. See also LEAD ASSEMBLY, ELECTRICAL; WIRING HARNESS (as modified); and CABLE ASSEMBLY (as modified). For items without inserts, see SHELL, ELECTRICAL CONNECTOR.

Part Alternates: 1008037A005, 1008-037-A005, 1008037A005000, 1008037A005-000, 10556102, 3577279040, 357-7279-040, 415063, 41-506-3, 819B3800, 819-B3800, 9115C1041, 5935-00-879-5366, 00-879-5366, 5935008795366 , 008795366

Electrical and Electronic Equipment Components | Connectors, Electrical

Supply Group (FSG) NSN Assign. NIIN
59 25 OCT 1967 00-879-5366

Drawings & Photos | NSN 5935-00-879-5366


Cross Reference | NSN 5935-00-879-5366

Part Number Cage Code Manufacturer
1008-037-A005 00795 DELTA ELECTRONICS MFG CORP
1008-037-A005 DG438 SEMIC RF ELECTRONIC GMBH
1008037A005-000 00795 DELTA ELECTRONICS MFG CORP
10556102 19200 US ARMY ARDEC RDECOM
357-7279-040 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
357-7279-040 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
41-506-3 43608 EDINBURGH CONNECTOR COMPANY DBA CONNECTRONICS
5935008795366 SCY13 E.C.A ETABLISSEMENT CENTRALD'APPROVISIONNEMENT DES
819-B3800 94375 AUTOMATIC CONNECTOR
9115C1041 87557 LOCKHEED CORP LOCKHEED ELECTRONICS CO INC
9115C1041 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5935-00-879-5366

Technical Data | NSN 5935-00-879-5366

Characteristic Specifications
BODY STYLE 9D STRAIGHT SHAPE
OVERALL LENGTH 1.125 INCHES NOMINAL
WIDTH ACROSS FLATS 0.500 INCHES NOMINAL
CONNECTOR LOCKING METHOD BAYONET PIN
CONNECTOR CABLE STRAIN RELIEF METHOD COMPRESSION NUT
CABLE ENTRANCE DIAMETER 0.115 INCHES MINIMUM AND 0.120 INCHES MAXIMUM
SHELL TYPE SOLID
SHELL MATERIAL COPPER ALLOY OR COPPER ALLOY 360
SHELL MATERIAL DOCUMENT AND CLASSIFICATION QQ-B-613,COMPOSITION 11,HALF HARD FED SPEC 1ST MATERIAL RESPONSE OR QQ-B-626,HALF HARD FED SPEC 2ND MATERIAL RESPONSE
SHELL SURFACE TREATMENT SILVER
SHELL SURFACE TREATMENT DOCUMENT AND CLASSIFICATION QQ-S-365 FED SPEC SINGLE TREATMENT RESPONSE
MATING END QUANTITY 1
CONTACT POSITION ARRANGEMENT STYLE ABBJ BNC SINGLE MATING END
INSERT MATERIAL PLASTIC POLYTETRAFLUOROETHYLENE SINGLE MATING END
INSERT MATERIAL DOCUMENT AND CLASSIFICATION ASTM-D-1710 ASSN STD SINGLE MATERIAL RESPONSE SINGLE MATING END
INCLUDED CONTACT QUANTITY 1 SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT REMOVABILITY NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING
INCLUDED CONTACT TYPE COAXIAL SOCKET SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS 500.0 SINGLE MATING END SINGLE CONTACT GROUPING
RADIO FREQUENCY TYPE CONTACT CHARACTERISTIC IMPEDANCE IN OHMS 50.0 SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT MAXIMUM FREQUENCY RATING 4.0 GIGAHERTZ SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT MATERIAL COPPER ALLOY OR COPPER ALLOY 360 SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT MATERIAL DOCUMENT AND CLASSIFICATION QQ-B-613 FED SPEC 1ST MATERIAL RESPONSE OR QQ-B-626 FED SPEC 2ND MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT SURFACE TREATMENT SILVER SINGLE MATING END SINGLE CONTACT GROUPING
CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION QQ-S-365 FED SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING
TERMINAL TYPE SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING
TERMINAL LOCATION BACK SINGLE MATING END SINGLE CONTACT GROUPING
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND SALT SPRAY PROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND PRESSURE PROOF
III OPERATING TEMP RATING -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
III PRECIOUS MATERIAL SILVER

Restrictions/Controls & Freight Information | NSN 5935-00-879-5366

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061680 ELEC WIRING PLUGS ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5935-00-879-5366

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic CodeT Other Electronics Equipment
Weapons Systems/End Item or Homogeneous GroupTQRechargeable batteries
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityAItem requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each