Product Details | TOGGLE SWITCH

5930-01-585-5998 A switch which is externally actuated by a lever and whose contacts open and close with an instantaneous (snap) action; includes items having one or more momentary positions. Includes switches (snap action) which use mercury to bridge contacts, and assemblages of complete switches (snap action) having common actuators. Excludes SWITCH, LEVER; SWITCH, ROTARY; SWITCH, KNIFE; SWITCH, SENSITIVE; and SWITCH, BOX.

Part Alternates: V1D1AH0CPZCZ7100, V1D1AH0C-PZCZ7-100, 5930-01-585-5998, 01-585-5998, 5930015855998, 015855998

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 28 MAY 2010 01-585-5998

Cross Reference | NSN 5930-01-585-5998

Part Number Cage Code Manufacturer
V1D1AH0C-PZCZ7-100 73559 CARLING TECHNOLOGIES, INC DBA CARLINGSWITCH

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-585-5998

Technical Data | NSN 5930-01-585-5998

Characteristic Specifications
SPECIAL FEATURES SINGLE POSITION; 20AMP, 12 VOLT; SEALED ILLUIMINATED SWITCH; NO LAMP; GREEN SUPER BRIGHT; FLUSH BRACKET BLACK IN COLOR; NO LENS; BLACK ACTUATOR COLOR; CONTURA V LASER ETCH ACTUATOR; HYDRA-CLAMP BODY
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 20.000 AMPERES RESISTIVE DC
PART NAME ASSIGNED BY CONTROLLING AGENCY V-SERIES CONTURA V SEALED ROCKER SWITCH
MAXIMUM VOLTAGE RATING IN VOLTS 12.0 DC

Restrictions/Controls & Freight Information | NSN 5930-01-585-5998

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information