NSN 5930-01-568-0293 76587, 01-568-0293, 015680293
Product Details | PRESSURE SWITCH
5930-01-568-0293 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Part Alternates: 76587, 5930-01-568-0293, 01-568-0293, 5930015680293, 015680293
Electrical and Electronic Equipment Components | Switches
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 16 OCT 2008 | 01-568-0293 | 00206 ( SWITCH, PRESSURE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-568-0293
Related Products | NSN 5930-01-568-0293
Technical Data | NSN 5930-01-568-0293
Characteristic | Specifications |
---|---|
PROOF PRESSURE | 500.00 POUNDS PER SQUARE INCH |
MOUNTING METHOD | THREADED STUD |
THREAD SERIES DESIGNATOR | NPT SINGLE THREADED STUD |
NOMINAL THREAD SIZE | 0.125 INCHES SINGLE THREADED STUD |
PRESSURE SWITCH TYPE | GAGE |
TERMINAL TYPE | TAB, SOLDER LUG |
CONTACT LOAD CURRENT RATING | 4.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CONTACT LOAD CURRENT RATING | 8.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
OPERATING TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
Restrictions/Controls & Freight Information | NSN 5930-01-568-0293
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |