Product Details | PROXIMITY SWITCH

5930-01-530-4973 A switch designed to perform the function of opening and/or closing one or more electrical circuits. The switching function is accomplished by means of separable contacts, semiconductor devices, or a combination of separable contacts and semiconductor devices. The item functions in response to electrical changes in its internal circuit caused by capacitance, inductance, or magnetic flux changes. It is activated by permanent magnets, metallic materials, or nonmetallic materials which come within its sensing range. For sensing switches which respond to changes other than capacitance, inductance, or magnetic flux, see SWITCH, AIRFLOW; SWITCH, CENTRIFUGAL; SWITCH, INERTIA; SWITCH, PRESSURE; SWITCH, PRESSURE-THERMOSTATIC; SWITCH, THERMOSTATIC; and SWITCH, TILT.

Part Alternates: NBN412GM60A2, NBN4-12GM60-A2, 102558, 5930-01-530-4973, 01-530-4973, 5930015304973, 015304973

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 31 MAY 2005 01-530-4973

Cross Reference | NSN 5930-01-530-4973

Part Number Cage Code Manufacturer
102558 SG480 SWE DISH
NBN4-12GM60-A2 66752 PEPPERL & FUCHS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-530-4973

Technical Data | NSN 5930-01-530-4973

Characteristic Specifications
OVERALL LENGTH 60.0 MILLIMETERS NOMINAL
WIDTH ACROSS FLATS 10.5 MILLIMETERS NOMINAL
CONTACT VOLTAGE RATING IN VOLTS 10.0 DC AT SEA LEVEL FIRST VOLTAGE 30.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 200.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE
OPERATING TEMP RATING -14.0 DEG FAHRENHEIT MINIMUM AND 158.0 DEG FAHRENHEIT MAXIMUM
SPECIAL FEATURES 4MM SENSING RANGE; 4 WIRE DC; HOUSING MATERIAL - NICKEL PLATED BRASS

Restrictions/Controls & Freight Information | NSN 5930-01-530-4973

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information