Product Details | THERMOSTATIC SWITCH

5930-01-528-1900 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: M24236/1-FGGFK, M242361FGGFK, MIL-S-24236/1, MILS242361, 5930-01-528-1900, 01-528-1900, 5930015281900, 015281900

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 04 MAR 2005 01-528-1900

Drawings & Photos | NSN 5930-01-528-1900


Demand History | NSN 5930-01-528-1900

Part Number Request Date QTY Origin
MILS242361 2011-01-31 38 US

Cross Reference | NSN 5930-01-528-1900

Part Number Cage Code Manufacturer
M24236/1-FGGFK 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M24236/1-FGGFK 89944 KOLLSMAN, INC.
MIL-S-24236/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-528-1900

Technical Data | NSN 5930-01-528-1900

Characteristic Specifications
STYLE DESIGNATOR 65 DISC W/FLANGE
OVERALL LENGTH 1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
OVERALL HEIGHT 0.638 INCHES NOMINAL
BODY DIAMETER 0.640 INCHES NOMINAL
BODY HEIGHT 0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 130.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 110.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE 28.0 DC AT ALTITUDE THIRD VOLTAGE
FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE
OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND

Restrictions/Controls & Freight Information | NSN 5930-01-528-1900

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information