NSN 5930-01-501-2332 352250005589, 43446985, 4344-69-85
Product Details | THERMOSTATIC SWITCH
5930-01-501-2332 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Part Alternates: 352250005589, 43446985, 4344-69-85, 5930-01-501-2332, 01-501-2332, 5930015012332, 015012332
Electrical and Electronic Equipment Components | Switches
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 26 SEP 2002 | 01-501-2332 | 00451 ( SWITCH, THERMOSTATIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-501-2332
Related Products | NSN 5930-01-501-2332
Technical Data | NSN 5930-01-501-2332
Characteristic | Specifications |
---|---|
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 450.0 DEG FAHRENHEIT MAXIMUM |
TEMP SENSING ELEMENT TYPE | DISC |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.108 INCHES MINIMUM AND 0.122 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.805 INCHES MINIMUM AND 0.819 INCHES MAXIMUM |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
Restrictions/Controls & Freight Information | NSN 5930-01-501-2332
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |