NSN 5930-01-408-7623 M24236/1-DLGKJ, M242361DLGKJ, MIL-PRF-24236/1
Product Details | THERMOSTATIC SWITCH
5930-01-408-7623 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Part Alternates: M24236/1-DLGKJ, M242361DLGKJ, MIL-PRF-24236/1, MILPRF242361, MIL-S-24236/1, MILS242361, 5930-01-408-7623, 01-408-7623, 5930014087623, 014087623
Electrical and Electronic Equipment Components | Switches
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 24 FEB 1995 | 01-408-7623 | 00451 ( SWITCH, THERMOSTATIC ) |
Demand History | NSN 5930-01-408-7623
Part Number | Request Date | QTY | Origin |
---|---|---|---|
MILPRF242361 | 2023-06-178 | 20 | Taiwan |
MILPRF242361 | 2011-05-137 | 2 | US |
MILS242361 | 2011-01-31 | 38 | US |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-408-7623
Related Products | NSN 5930-01-408-7623
Technical Data | NSN 5930-01-408-7623
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 64 DISC W/FLANGE |
OVERALL LENGTH | 1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
OVERALL HEIGHT | 0.469 INCHES MINIMUM AND 0.709 INCHES MAXIMUM |
BODY DIAMETER | 0.540 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
BODY HEIGHT | 0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | 170.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 155.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | BRACKET AND SLOT AND UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.133 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
MOUNTING SLOT WIDTH | 0.133 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.930 INCHES MINIMUM AND 0.944 INCHES MAXIMUM |
TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/1 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-24236/1 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M24236/1-DLGKJ |
Restrictions/Controls & Freight Information | NSN 5930-01-408-7623
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 657 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5930-01-408-7623
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |