Product Details | PRESSURE SWITCH

5930-01-407-2442 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Part Alternates: 96200BB3, 96200-BB3, 5930-01-407-2442, 01-407-2442, 5930014072442, 014072442

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 24 JAN 1995 01-407-2442

Drawings & Photos | NSN 5930-01-407-2442


Cross Reference | NSN 5930-01-407-2442

Part Number Cage Code Manufacturer
96200-BB3 89326 BARKSDALE INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-407-2442

Technical Data | NSN 5930-01-407-2442

Characteristic Specifications
STYLE DESIGNATOR 4 CYLINDRICAL
OVERALL LENGTH 3.520 INCHES NOMINAL
OVERALL DIAMETER 1.130 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 2000.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH
CONTACT VOLTAGE RATING IN VOLTS 250.0 AC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD THREADED STUD
THREAD SERIES DESIGNATOR NPT SINGLE THREADED STUD
NOMINAL THREAD SIZE 0.250 INCHES SINGLE THREADED STUD
III END ITEM IDENTIFICATION TRASH COMPACTOR, CHICAGO TRASHPACKERS CORP

Restrictions/Controls & Freight Information | NSN 5930-01-407-2442

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information