Product Details | PUSH SWITCH

5930-01-344-9701 A switch that is externally actuated by a device such as a push rod or button, which requires pushing for each actuation. The action may be momentary, with mechanical return. The actuating device may or may not be an integral part of the switch. The item may include provisions for mounting indicating lamp(s) or light emitting diode(s) in the actuator. Includes items consisting of individually separable switches that are physically interlocked, that have a common actuator, or are electrically connected. Excludes LIGHT-SWITCH; LIGHT-SWITCH ASSEMBLY; SWITCH, BEAM SELECTING, HEADLIGHT; SWITCH, FOOT; SWITCH, INTERLOCK; SWITCH, PRESSURE; SWITCH, PUSH-PULL; SWITCH, SENSITIVE and SWITCH ASSEMBLY. For devices which start, stop, reverse, select and/or regulate the speed of a motor, see STARTER, MOTOR and CONTROLLER, MOTOR.

Part Alternates: SC6553884, SC655388-4 , 80010A1C2D2L2N1R, 5930-01-344-9701, 01-344-9701, 5930013449701, 013449701

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 08 SEP 1991 01-344-9701

Cross Reference | NSN 5930-01-344-9701

Part Number Cage Code Manufacturer
800-10-A1C2D2L2N1(R) 96182 EATON CORPORATION DBA AEROSPACE & COMMERCIAL DIVISION
SC655388-4 K3743 BAE SYSTEMS GLOBAL COMBAT SYSTEMS LIMITED
SC655388-4 K6894 BAE SYSTEMS RO DEFENCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-344-9701

Technical Data | NSN 5930-01-344-9701

Characteristic Specifications
NONPILE-UP CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.000 AMPERES RESISTIVE AC
INCLOSURE TYPE FULLY INCLOSED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION MOISTURE PROOF

Restrictions/Controls & Freight Information | NSN 5930-01-344-9701

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information