Product Details | THERMOSTATIC SWITCH

5930-01-233-3147 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: NC920043, NC9-20043, NH22223297, NH2-222-3297, 22210NH22223292, 222-10NH2-2223292, 5930-01-233-3147, 01-233-3147, 5930012333147, 012333147

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 29 MAY 1986 01-233-3147

Demand History | NSN 5930-01-233-3147

Part Number Request Date QTY Origin
222-10NH2-2223292 2023-09-250 1 DIBBS
NC9-20043 2023-09-250 1 DIBBS
222-10NH2-2223292 2022-12-354 1 DIBBS
NC9-20043 2022-12-354 1 DIBBS
222-10NH2-2223292 2020-03-64 1 DIBBS
NC9-20043 2020-03-64 1 DIBBS
222-10NH2-2223292 2019-05-127 1 DIBBS
NC9-20043 2019-05-127 1 DIBBS
222-10NH2-2223292 2019-01-27 1 DIBBS
NC9-20043 2019-01-27 1 DIBBS
5930-01-233-3147 2018-05-142 2 DIBBS
5930-01-233-3147 2018-04-108 2 DIBBS

Cross Reference | NSN 5930-01-233-3147

Part Number Cage Code Manufacturer
222-10NH2-2223292 19278 DETROIT SWITCH, INC.
NC9-20043 88234 UNITED ELECTRIC CONTROLS COMPANY
NH2-222-3297 96452 AMERICAN STANDARD INC CONTROLS DEPT PRODUCTS GROUP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-233-3147

Technical Data | NSN 5930-01-233-3147

Characteristic Specifications
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 3.281 INCHES NOMINAL
CONTACT LOAD CURRENT RATING 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE
OVERALL LENGTH 5.188 INCHES NOMINAL
CONTACT ADJUSTMENT RANGE +90.00 TO 165.00 ACTUATION POINT DEGREES FAHRENHEIT AND +88.00 TO 163.00 DEACTUATION POINT DEGREES FAHRENHEIT
OVERALL HEIGHT 8.875 INCHES NOMINAL
CONTACT VOLTAGE RATING IN VOLTS 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE
TERMINAL TYPE SCREW
CONTACT LOAD CURRENT RATING 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
BODY HEIGHT 2.750 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 0.656 INCHES NOMINAL
CONTACT LOAD CURRENT RATING 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
OVERALL WIDTH 2.812 INCHES NOMINAL
CONTACT LOAD CURRENT RATING 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
CONTACT LOAD CURRENT RATING 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS 230.0 DC AT SEA LEVEL SIXTH VOLTAGE
CONTACT ACTION STIMULUS INCREASE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 2.406 INCHES NOMINAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WATERTIGHT
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
CONTACT VOLTAGE RATING IN VOLTS 440.0 AC AT SEA LEVEL THIRD VOLTAGE
CONTACT LOAD CURRENT RATING 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE
FEATURES PROVIDED ELECTRICAL ACCESS PORT
STYLE DESIGNATOR RECTANGULAR
UNTHREADED MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL
CONTACT VOLTAGE RATING IN VOLTS 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CONTACT LOAD CURRENT RATING 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE
TEMP SENSING ELEMENT TYPE BULB
CONTACT VOLTAGE RATING IN VOLTS 230.0 AC AT SEA LEVEL SECOND VOLTAGE
OPERATING TEMP RATING 165.0 DEG FAHRENHEIT MAXIMUM
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT VOLTAGE RATING IN VOLTS 550.0 AC AT SEA LEVEL FOURTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS 115.0 DC AT SEA LEVEL FIFTH VOLTAGE

Restrictions/Controls & Freight Information | NSN 5930-01-233-3147

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-233-3147

Category Code Description
Cognizance Codes3BNavy-owned stocks of field level repairable DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityDField Level Reparables
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each