Product Details | THERMOSTATIC SWITCH

5930-01-228-8712 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: DRSSVPC0RP176F, DR-SSV-PC0RP176F, DRSSVPCORP176FST, DR-SSV-PCORP176FST, GT830AB7, 5930-01-228-8712, 01-228-8712, 5930012288712, 012288712

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 22 MAR 1986 01-228-8712

Cross Reference | NSN 5930-01-228-8712

Part Number Cage Code Manufacturer
DR-SSV-PC0RP176F 04814 CHATHAM CONTROLS CORP
DR-SSV-PCORP176FST 04814 CHATHAM CONTROLS CORP
GT830AB7 26512 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-228-8712

Technical Data | NSN 5930-01-228-8712

Characteristic Specifications
OPERATING TEMP RATING -65.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.000 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
UNTHREADED MOUNTING HOLE DIAMETER 0.124 INCHES MINIMUM AND 0.129 INCHES MAXIMUM
OVERALL LENGTH 1.250 INCHES NOMINAL
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
TERMINAL TYPE TAB, SOLDER LUG
CONTACT VOLTAGE RATING IN VOLTS 28.0 DC AT SEA LEVEL SECOND VOLTAGE
FEATURES PROVIDED HERMETICALLY SEALED CASE
OVERALL HEIGHT 0.410 INCHES MAXIMUM
CONTACT ACTION STIMULUS INCREASE
CONTACT LOAD CURRENT RATING 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT STIMULUS RATING 176.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
OVERALL WIDTH 0.380 INCHES MAXIMUM
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
PRECIOUS MATERIAL AND LOCATION TERMINAL SURFACES GOLD AND CONTACTS PLATINUM AND CONTACTS IRIDIUM
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE
PRECIOUS MATERIAL GOLD AND PLATINUM AND IRIDIUM
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION

Restrictions/Controls & Freight Information | NSN 5930-01-228-8712

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:CItem contains two or more precious metals
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-228-8712

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each